We manufacture a wide variety of heating equipment for residential, commercial, agricultural, and industrial use. All of our products are 100% North American made, and are covered by our industry best 4 Year "No Ifs, Ands, or Buts" Guarantee |
![]() |
Heat a person, heat a spot, heat a building with the Easy Radiant High Intensity infrared heater. Available in inputs of 30,000 to 200,000 BTUH, single and 2 stage, NG or LP fired. 120V, 24V, and millivolt controlled models available. |
THE HEATER
|
HIGH INTENSITY HEATAt the heart of the high intensity heater is an atmospheric type, 100% primary air burner utilizing a perforated ceramic combustion surface. The flame causes the ceramic surface to reach incandescent temperature of approximately 1700° to 1850°F. A high rate of infra-red energy is generated, and directed to where it is needed.APPLICATIONSHigh intensity units excel in situations where large amounts of directed, focused heat energy is required. Spot heating and heat recovery are some common high intensity applications. The compact size of the units also allow them to be used in areas where other heating equipment might not fit. |
![]() |
![]() |
![]() |
![]() |
|
DIMENSONS
|
RA-30 - RA-60 |
RA-70 - RA-100 |
RA-110 - RA-150 |
RA-160 - RA-200 |
WIDTH |
16 3/4" |
25 1/4" |
33 7/8" |
42 1/2" |
LENGTH |
28 5/8" |
28 5/8" |
28 5/8" |
28 5/8" |
DEPTH |
8 3/4" |
8 3/4" |
8 3/4" |
8 3/4" |
CLEARANCES |
||||
SIDE |
30" |
36" |
46" |
48" |
BACK |
30" |
30" |
33" |
33" |
TOP (0 - 29 DEG.) |
60" |
62" |
64" |
68" |
TOP (30 DEG.) |
48" |
50" |
58" |
68" |
BELOW |
80" |
105" |
125" |
140" |
TYP. MOUNT HEIGHT |
||||
HORIZONTAL* |
11' - 14.5' |
15' - 17' |
17' - 18.5' |
19' - 20.5' |
ANGLE* |
10' - 13' |
13' - 15' |
15' - 16'5' |
17' - 18.5' |
Add suffix "D" for 120 volt control or "Q" for 24 volt control |
Add suffix "SAN" for automatic spark ignition, natural gas |
Add suffix "SAL" for automatic spark ignition, Propane |
Add suffix "TAN" for millivolt control, natural gas |
Add suffix "TAL" for millivolt control, propane |
![]() |
Operation and Installation Instructions for Single Stage |
![]() |
Operation and Installation Instructions for Two Stage |
![]() |
Engineering Submittal |
![]() |
All of our products have been tested to CSA/CGA & AGA standards Intertek ETL Laboratories to 100% compliance with both Canadian and US gas code. 100% insurance company approved! |
|